4.6. Smith with Intelli-vent device. It will be far better if you call a certified technician to deal with this issue. Fix the loose wiring and replace the damaged wires. This applies both to the choice of materials and components used in the manufacturing process, as well as to the efficiency of the finished products. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. FIX: Connections or breakage of wires of the flow adjustment valve, scale buildup on the motor drive which gets locked, water leakage. View more. Thank you. If you install the unit professionally and maintain it according to the manual, it will support you for up to 10 years. The national average is 67.5. Very simple. In other words, the thermopile itself gets defective or the wire connectors come loose. This is the final error code for thermistor failure. {{INUSING}}, The average cost per Gallon is ${{PROPANEGASPRICE}}
We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. 113 Flame On Should be Off Fail CODE: 39, 391, Two timesPROBLEM: Problem with the air-fuel ratio rod - AFR. Then, shut off the main gas supply valve. Before developing Water Heater Hub, Anthony Barnes was a full-time plumber, and he has undertaken a wide variety of projects over the decades. What Does Flashing Light Mean On Ao Smith Water Heater? To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. This final error code indicates that there is a false flame being detected within your water heater. Install a new gas control valve and tighten it up using the 4 gas pipe by turning it clockwise. Press the red reset button inward until you hear a click. Then, use a flathead screwdriver to remove the nuts that hold the upper access panel in its place. Visually inspect the thermistor connections. Now, press the red button to reset the unit successfully. You can do a few basic checks first like making sure there are no loose wire connections or soot on the flame rod. As a result, you can now easily diagnose your water heater that will save you both time and money. Solution: Ensure the flow sensor wires are correctly connected and with no damage. Leak Watch Smart technologyimmediately alerts you of a leak for yourpeace of mind. Problem: Problem with the computer board. Can you hear a buzzing spark ignition from the burner or two clunk sounds from the gas valve? Smith INTELLI-VENT Page 1 INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters Printed in the USA - 0605 Part No. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Solution: Check if the condensate drain is installed on the vent collar of the heater. Smith Water Heater error code guide will explain common issues, provide tips, and show you how to read your model's error codes. CODE: 441, Two timesPROBLEM: Problem with the flow sensor. Revision 2 includes updated troubleshooting information for error codes 3, 4, and 6. You are using an out of date browser. It will be convenient for the homeowners who are handyman at the same time. Some of the problems are common, and they do not include an error code: Water is not hot enough or is too hot The temperature of the exiting water fluctuates Noise Burner does not ignite Long time to get hot water Sediment buildup If there is no scale, then you should also check the connections and wires for damage or looseness. A.O. If yes, its because the pilot light got extinguished recently and the thermopile is cooling down. Understanding Noritz error codes and troubleshooting Noritz water heaters. Besides, I will also walk you through the troubleshooting steps to clear those error messages. Ask a customer care specialist Replacing the gas control valve/thermostat will be a simple fix to this issue. They have to make sure that it can function properly. An Easy Guide on How to Fix A Squeaky Door Without Taking It Apart, How to Remove A Broken Drill Bit from Wood? Bathtub faucets typically have a flow rate of 5 Gallons per Minute. Launch Product Selector. How to troubleshoot Rinnai water heaters successfully using Rinnai error codes guide. What should you do first is- turn the gas control valve to the off position. AO Smith electric water heater keeps shutting off, e02 mike4500 Jun 18, 2019 M mike4500 Premium Member Joined Jun 18, 2019 Messages 5 Location NJ Jun 18, 2019 #1 Model Number 50 g Brand -brand- Age 1-5 years I have an AO Smith 50 gallon with the electronic display. This error code occurs when there is a problem with the inlet thermistor. However, there is a four pin white plug in the water heaters junction box that I believe is the connector for the smart grid module, and two of the wires have come out of the pin/connector. F1-7 Fault Code, LFFU14F5HWD Frigidaire freezer won't shut off. Register now, spots are limited! Try our Product Selector Tool to find the right models for your needs-for both heating and treating your home's water. He has a good standing reputation for superior skills in heating, air conditioning, hot water tanks, and indoor air quality systems. Its normal. Read to know in details. forms: { So, check the previous chapter again. They have to pay attention to the two sounds of clunk found from the water heaters gas valve. How To Fix: First off, turn the gas control knob to the off position. Solution: Check wires and computer board for damages. Sometimes if you are lucky, it could just be a bit of soot blocking the sensors other times, you may need to find a replacement AFR rod as soon as possible. Follow the below steps to change the part correctly: Your AO Smith Water Heaters status light will blink 5 times every three seconds if the temperature sensor gets defective. Again, this is an issue for a professional but you can check that the proper settings are in place on the computer board. Smith - Troubleshooting help - Hello my frist post here. Your AO Smith Water Heater's status light will blink 5 times every three seconds if the temperature sensor gets defective. Related Price Pages:A.O. Afterward, put everything back into its place. But if you have to increase the water temperature, try to stay well below 150F (65C) so the high limit switch doesn't trip. Nevertheless, it will mean that people have to learn more about Ao Smith Water Heater Codes for understanding the error and the solution. The cookie is used to store the user consent for the cookies in the category "Analytics". The fan motor could also be blocked by dust, debris or dirt and needs a clean. Trouble codes on the AO Smith Water Heater mean your water heater is not working properly. How long does an A.O. b. To have the unit working properly, it has to be supplied with the power and correct connection. Eric Alvarez is an HVAC guy based in El Paso, Texas, United States. FIX: Check for blockage in the vents, the distance between the intake and exhaust terminals are per instructions and remove if there is grease or dirt in the gas burner and fan motor. Too High Temperature 2. Solution: Connections or breakage of wires of the flow adjustment valve, scale buildup on the motor drive which gets locked, water leakage. Why is my AO Smith water heater not lighting? Tankless water heater problems and how to repair models from Noritz, Rinnai, Takagi using error codes. This numerical code is telling you about the ignition failure. Introducing X3 Scale Prevention Technology on our Condensing Gas Tankless Water Heaters. CODE: 70, 701, One timePROBLEM: Problem with the computer board. Then, hand-tighten the thermistor first. To solve this problem, you will need to find the correct settings for your water heaters model and reset them on the computer board. This is an in-depth guide on AO Smith Water Heater Troubleshooting Codes. Before doing so, don't forget to check the wiring attached to the control board. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. CODE: 711, One timePROBLEM: Gas solenoid valve drive circuit failure. In other words, when the sensor senses the water temperature is too high, it will throw this error code. This website uses cookies to improve your experience while you navigate through the website. Whats the average air temperature in the room where your water heater will be installed? Turn the gas supply on and check for leaks by spraying soap solution on the connections. But opting out of some of these cookies may affect your browsing experience. To solve this issue, you need to check for any condensation within the heater. I have tested the power at the thermostat and the elements with a multi meter and they all check out fine. Generally, the water gets too hot if the gas control valve/thermostat is at fault. c. The computer checks for any problems with the unit before startup. Now, relight the pilot light by following the step-by-step guide I mentioned earlier in this article. Otherwise, the status light wont blink. Takagi Water Heater Error Codes [Ultimate Guide], AO Smith Electric Water Heater Troubleshooting, AO Smith Water Heater Troubleshooting Codes, AO Smith Gas Water Heater Troubleshooting, 9 AO Smith Gas Water Heater Troubleshooting Tips, AO Smith Water Heater Not Heating [5 Easy Solutions], Bosch Tankless Water Heater Maintenance [The Complete Guide], Bosch Tankless Water Heater Troubleshooting [A Complete Guide], Bosch Tankless Water Heater Error Codes [Ultimate Guide]. d. Igniter activates. Wait for ten minutes to allow all the gas to clear out. For example, a model 510 will display the numerical code on the 7-Seg LED on the computer board, while the 110 and 310 models only a blinking red LED that can flash one time or more. On the other hand, your AO Smith Water Heater goes through problems if the status light flashes more than 1 times followed by a three-second pause. Summary of Contents for A.O. And this will reset the water heater successfully. Read also : Noritz Error Code Troubleshooting. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. People can find those advantages from AO Smith tankless water heater. Smith Water Heater Troubleshooting. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Reasons Why There Is Water Leak Inside Refrigerator, Why Does My Air Conditioner Keep Freezing Up? AFR rods monitor the air fuel ratio of your water heaters internal combustion engine, which is a massively important part of your water heaters function. Once you confirm the issue, turn off the gas control knob. Main Menu. Connect the water line and turn on the heater to see the flow of water. Analytical cookies are used to understand how visitors interact with the website. And this guide on AO Smith Water Heater Troubleshooting Lights broke down everything you need to know. This cookie is set by GDPR Cookie Consent plugin. If you have recently experienced cold weather, it could also be that your connectors are frozen and need warming up. Continue with Recommended Cookies. I Save my name, email, and website in this browser for the next time I comment. First, the pilot light wont come on until you try to light it up. The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". The tools needed to solve the problems from below are mainly the screwdriver, manometer, and multi-meter. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. Smith Signature 100 50-Gallons Tall 6-year Limited Warranty 4500-Watt Double Element Electric Water Heater Model # E6-50H45DV Find My Store for pricing and availability 2930 A.O. 13 February 2021; Non class; 0 Comments The AO Smith water heater is too hot. So, the corrective action you need to take is- check the thermopile and replace it if it gets defective. You can read this article on Rheem Water Heater Leaking. Just turn on a hot water faucet and let the water run for several minutes. The thermostat(s) on this water heater have been factory set to 120F to reduce the risk of scald injury. Get Help from a Local Plumber. Not only that, but it also causes the Pentair pool heater to turn off. How To Fix: To fix this issue, you should replace the control board. Is Spray Paint Flammable? We are going to cover some of the most common error codes and problems seen with the AO Smith tankless water heater so you know what you can do when the issue occurs. In one of the other places I manage, the owner -- for reasons known best to herself -- had a State Electric Hybrid water heater installed. Just shut off the electric supply to the unit. Two consecutive flashes every three second stand for thermopile voltage issue. Though resetting the unit will fix and clear the error code, you must figure out whats overheating the water. You can now use this knowledge to help diagnose and fix problems with your AO Smith tankless water heater so you can continue enjoying hot water with little fuss! FIX: Is the water heater set for the right elevation? FIX: Check for the proper settings on the computer board. var intYear = dteNow.getFullYear();
Typically, a bad thermostat, burn-out heating elements, and bad computer board are some defects that cause this issue. Our comprehensive A.O. CODE: 03 (031), One timePROBLEM: Incorrect dipswitch settings. I replaced it with another AO Smith model, but a more base model without the smart module option. Next, check for water leaks and fix them if needed. The 4-chamber model of AO Smith Electric Tankless Water Heater only throws this error code. To view or adjust our assumptions of the most common factors that impact this products performance using National Averages, please view the
The error code may also be flashing three times. Hi, On an Electric AO SMITH Smart Water Heater, if the diag light is a solid red (looks more orange) right after you flip breaker on and the smart panel has no lights/codes. The consent submitted will only be used for data processing originating from this website. (function() { If the resistance of this part goes out of range, you must replace it. It sounds like the main control is malfunctioning, what's the complete model number of this water heater? See Figure 4. FIX: Check for connection/breakage of wires, corrosion or frozen connectors, fan motor covered with the dust, burn marks on the computer board. Clean the gas pipes properly if they are clogged and do not forget to turn off the valve before cleaning. Necessary cookies are absolutely essential for the website to function properly. So, keep reading. Yesterday morning my water heater was beeping but no error code. What could that be? However, there is no need to be panicked because they have the solution for this circumstance. This error code may appear when you power up the unit. Empty all the water that has accumulated in the exchanger properly. Possibly a short somewhere, check all your wires for frayed or cut insulation on them shorting out. CODE: 32, 321, Two timesPROBLEM: Inlet thermistor failure. Turn the valve back on and set the pressure to the proper temperature. So, check out the section again. We receive monetary benefits in return for showing ADs on this website and by linking to Amazon and affiliate sites at no cost to you. Check if there are any foreign particles or grease on the gas burner and fan motor. If you see any scale buildup on your motor drive, you will need to clean it away with hydrochloric acid and water mixture (wear appropriate protection gear while handling this mixture). Smith Water Heater Prices. These stats are based on a home in Nolensville, TN To view or adjust our performance assumptions, view advanced settings. document.write(intYear);
The Pentair error code E05 indicates an open stack flue sensor. Pentair Heater E05 Error Code [Reasons + Solutions]. This prevents proper connectivity between the system and the sensor, causing the heater to shut down and display the E05 error code. Water Heaters. A thin or low flow of water to or from the water heater can also cause the e05 on Pentair heater display. Smith water heater last? Malfunctioning Control Board 4. You can see the flash code once you relight the pilot light. Alternatively, the error code will flash four times. GTC-070 R3 Revision 2 includes updated troubleshooting information for error codes 3, 4, and 6. e. ); A water heater leaks from different places like from the top, bottom, and side. {{INUSING}}, The average cost per Mcf is ${{NATURALGASPRICE}}
This is usually caused by scale build up which locks the motor drive. Alarm reads E05 and a lot of water is going thru the overflow drain pipe It's still under warranty. You can either left-click on the link to open the manual in a new tab or right-click and save a copy directly on your computer. BFC Cyclone Twister II CODE: 11 (111), Three timesPROBLEM: The ignition failure. CODE: 99, 991, Five timesPROBLEM: Improper gas combustion. Gas Tank; Electric Tank; Hybrid Tank; Expansion Tanks; Tankless . Your AO Smith Water Heater wont light up if there are electrical problems like the thermopile wires come loose. There will be various considerations which should be made in this circumstance for finding the perfect one. 50 Gallon Tall 12-Year Energy Smart 5500/5500-Watt Elements Electric Water Heater with Leak Detection Model: EE12-50H55DVF Lowe's Item #: 3806368 Shop Now at Lowe's Product Description iCOMM Smart Connectivity allows you to get notifications and manage your water heater from your smartphone